    PROSOFT MVI56-PDPMV1 Master Network Interface Module The MVI56 PROFIBUS DP-V1 Master Network Interface Module allows ControlLogix processors to easily communicate with slave devices supporting PROFIBUS DP-V0 and DP-V1 protocol. The module acts as an input/output module between the PROFIBUS network,The MVI56-PDPMV1 is a communication module that functions as a Profibus DP V1 Master communication module, enabling any ControlLogix controller to connect with existing or new PROFIBUS network and communicate with up to 125 PROFIBUS slaves. This module is also compatible for use with PROFIBUS repeaters to maximize slave device connection . The module incorporates proprietary backplane technology that enables powerful data exchange with ControlLogix processors

    PROSOFT MVI56-PDPMV1

    The module acts as an input/output module between the PROFIBUS network and the ControlLogix processor. Data transfer from the processor is asynchronous with the I/O data transfer on the PROFIBUS network. Databases are user-defined and stored in the module to hold the data required by the protocol.


    Specifications

    Single Slot - 1756 backplane compatible

    The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module

    Ladder Logic is used for data transfer between module and processor. Sample ladder file (add-on instruction) included.

    Local or remote rack

    Configurable I/O backplane sizes allow optimal performance for remote rack applications

    CIPconnect™ enabled. Module supports communications with ProSoft Configuration Builder and FDT comDTM via Ethernet routing using Rockwell Automation Ethernet interface.


    Specification

    Description

    Backplane Current Load

    800 mA @ 5.1 VDC
    3mA @ 24 VDC

    Operating Temperature

    32° F to 140° F (0° C to 60° C)

    Storage Temperature

    -40° F to 185° F (-40° C to 85° C)

    Shock

    30 g Operational
    50 g non-operational

    Vibration

    5 g from 10 to 150 Hz

    Relative Humidity

    5% to 95% (without condensation)

    LED Indicators

    Module Status

    Backplane Transfer Status

    Application Status

    Serial Activity and Error LED Status

    Debug/Configuration port (CFG)

    CFG Port (CFG)

    RJ45 (DB-9M with supplied cable)

    RS-232 only

    CIPconnect™ Ethernet routing using 1756-ENBT, 1756-EN2T or similar

    Shipped with Unit

    RJ45 to DB-9M cables for each port

    6-foot RS-232 configuration cable